Configuration Mode (ConF)
Code Nam e / De s cription Adjustment range Factory s e tting
JG
t
*
(1)
[Jog delay]
0 to 2.0 s 0.5 s
Anti-repeat delay betw een 2 consecutive jog operations.
This parameter can be accessed if
[JOG]
(JOG) is not set to
[No]
(nO).
(1) The parameter can also be accessed in the
[SETTINGS]
(SEt-)
menu.
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from w ithin the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.
Parameter that can be modified during operation or w hen stopped.
To change the assignment of this parameter, press the ENT key for 2 s.
Parameters described in this page can be accessed by:
DRI- > CONF > FULL > FUN- > JOG-
2 s
*