Configuration Mode (ConF)
Code Nam e / De s cription Adjustment range Factory setting
PES
nO
A11
A12
A13
OA01
...
OA10
[Weight sensor ass.]
[No]
(nO)
WARNING
LOSS OF CONTROL
•
Verify that
[Point 1 X]
(LP1),
[Point 2x]
(LP2),
[Point 1Y]
(CP1) and
[Point 2Y]
(CP2) are correctly
set to avoid los s of control of the load being lifted.
•
Perform a com prehensive com missioning tes t to confirm the value given to the param eters
[Point 1 X]
(LP1),
[Point 2x]
(LP2),
[Point 1Y]
(CP1) and
[Point 2Y]
(CP2).
Failure to follow these instructions can result in death, serious injury, or equipment damage.
This
paramete r
can
be
configured
if
[BRA K E
LOGIC
CON T R O L]
(
bLC
-
)
page
194
is
not
set
to
[No]
(
nO
).
[No]
(nO): Not assigned
[Al1]
(A11): Analog input A1
[Al2]
(A12): Analog input A2
[Al3]
(A13): Analog input A3
[RP]
(PI): Pulse input
[AI virtual 1]
(AIU1): Virtual analog input 1 w ith the jog dial
[AI virtual 2]
(AIU2): Virtual analog input 2 by the communication bus
[OA01]
(OA01): Function blocks: Analog Output 01
...
[OA10]
(OA10): Function blocks: Analog Output 10
LP1
*
[Point 1 X]
0 to LP2-0.01% 0%
0 to 99.99% of signal on assigned input.
[Point 1x]
(LP1) must be less than
[Point 2x]
(LP2).
This parameter can be accessed if
[Weight s ensor as s.]
(PES) is assigned.
CP1
*
[Point 1Y]
-1.36 In to 1.36 In (1) -In (1)
Current corresponding to load
[Point 1 X]
(LP1), in A.
This parameter can be accessed if
[Weight s ensor as s.]
(PES) is assigned.
LP2
*
[Point 2X]
LP1+0.01% to 100% 50%
0.01 to 100% of signal on assigned input.
[Point 2x]
(LP2) must be greater than
[Point 1x]
(LP1).
This parameter can be accessed if
[Weight s ensor as s.]
(PES) is assigned.
CP2
*
[Point 2Y]
-1.36 In to 1.36 In (1) 0 A
Current corresponding to load
[Point 2x]
(LP2), in A.
This parameter can be accessed if
[Weight s ensor as s.]
(PES) is assigned.
IbrA
*
[Ibr 4-20 mA loss]
0 to 1.36 In (1)
0
Brake release current in the event of the loss of the w eight sensor information.
This parameter can be accessed if the weight sensor is assigned to an analog current input and the 4-20 mA loss is deactivated.
Recommended settings: Rated motor current for a hoisting application.
(1)
In corresponds to the rated drive current indicated in the Installation manual and on the drive nameplate.
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from w ithin the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.
Parameter that can be modified during operation or w hen stopped.
*