Configuration Mode (ConF)
Code Nam e / De s cription Adjustment range Factory setting
tLC
*
[Analog limit. act.]
[Ye s ]
(YES)
This parameter cannot be accessed if
[Torque lim it. activ.]
(tLA)
is set to
[No]
(nO).
Identical to
[Torque lim it. activ.]
(tLA)
page 216.
If the assigned input or bit is at 0:
The limitation is specified by the
[M otoring torque lim ]
(tLIM)
and
[Gen. torque lim .]
(tLIG)
parameters if
[Torq u e
limit .
activ.]
(
tL
A
)
is
not
[No]
(
nO
).
No limitation if
[Torque limit. activ.]
(tLA)
is set to
[No]
(nO).
If the assigned input or bit is at 1:
The limitation depends on the input assigned by
[Torque re f. as s ign.]
(tAA).
Note:
If
[Torque lim itation]
(tLA)
and
[Torque re f. as sign.]
(tAA)
are enabled at the same time, the low est value w ill be
taken into account.
(1) The parameter can also be accessed in the
[SETTINGS]
(SEt-)
menu.
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from w ithin the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.
Parameter that can be modified during operation or w hen stopped.
*