NOTICE!
Risk of severe material damage due to a delayed shut-down
in the event of a malfunction!
A delayed shut-down in the event of malfunction can cause per-
manent damage to the Börger machine.
— In the event of a malfunction, shut down the Börger machine
and all upstream and downstream system components imme-
diately until the cause has been rectified.
Fault Possible causes Fault elimination
The Bioselect does not start, or
runs with difficulty after a down-
time
Solids from the substrate have
become encrusted and are blocking
the rotating parts
— Run the Bioselect backwards
without feed for a short period of
time (changing the direction of
rotation)
— Release the tension spring(s),
briefly switch on the Bioselect,
tighten the tension spring(s)
again, or, in case of pneumatic
adjustment, release the pressure,
briefly switch on the Bioselect,
pressurize again
—
Clean the compactor unit, lubri-
cate the adjustment mechanism
—
Clean the interior / auger shaft
Wedge wire screen or rotation lock is
deformed (e.g. by foreign bodies) and
blocks the brush auger
— Replace the wedge wire screen
Gear motor incorrectly mounted or
connected
— Install the solid shaft of the sepa-
rator into the hollow shaft of the
gear unit according to the oper-
ating manual from the drive man-
ufacturer
— Ensure that the electrical connec-
tion is free of faults and that the
power supply is reliable
Drive output too low
— Install the correct drive
Brush auger is frozen to the
wedge wire screen
— Defrost the machine and protect it
against frost
Operation
BA-RC40_EN, 17.01.2024www.boerger.de / www.boerger.com104