Fault Possible causes Fault elimination
Insufficient or no material is dis-
charged from the thick matter
outlet
Incorrect flow direction / direction of
drive rotation
Change the direction of drive rota-
tion
Feed line closed or blocked
Open the shut-off devices
Clean the feed line
The feed connection leaks
Tighten the screws on the flange
connection cross-wise with uni-
form strength
Check/replace the seal
Check the pipes for damage and
rectify, if necessary
Rule out leaks in other compo-
nents
DS content of the substrate too low
Only use the Bioselect as
intended, i.e. for digestate and
liquid manure in accordance with
Ä
Chapter 2.3 “Proper use”
on page 15.
The brush auger is clogged with mate-
rial and is consequently unable to
transport material
Clean the brush auger
Eliminate the cause (e.g. working
pressure too high)
Press channel, or filter press channel
for HP version, blocked
Repeatedly run the Bioselect
without feed alternately back-
wards and forwards (changing the
direction of rotation)
Clean press channel or filter press
channel for HP version
Multi Disc jammed
Rectify jam
Reduce pre-tension, if necessary
Lubricate adjustment mechanism
Pre-tension of tension spring(s) too
high
Reduce pre-tension
Operation
BA-RC40_EN, 17.01.2024 www.boerger.de / www.boerger.com 105