NOTE!
Separation of fibers
In order to ensure that the fibers are separated from the system,
the fibers should be larger than the slot opening width of the
wedge wire screen. The ideal slot opening width of the screen for
the DS contents and DS qualities required can be different
depending on the separation medium.
Pressure limits
Pressure resistance of the screen
Max. differential pressure
2 bar
29 psi
Separation effect
Min. differential pressure
80 - 200 mbar
1.16 - 2.90 psi
The pressure limits during operation of the Bioselect RC separator
are oriented at the operating conditions.
For example, in the case of gravity feed operation without using a
control unit, lower pressure operating limits must be adhered to.
A control unit should always be used whenever the substrate is fed
via a pump. Otherwise, low pressure operating limits must also be
adhered to in this case.