with control unit without control unit
Minimum 8A 8A
Optimum 15A < 11A
Short-term 16A 16A
Maximum 18A 18A
* values at 400V 50Hz
NOTICE!
Risk of material damage if the limit of the current consump-
tion is exceeded!
The current consumption must not exceed the limit of 18 A. Oth-
erwise, malfunctions or even lasting damage to the wedge wire
screen and the motor may occur.
If the brush auger is stuck in the solid matter such that the
brush auger can no longer be released / moved backwards,
the Bioselect RC separator would require manual cleaning as
described in
Ä
Chapter 6.1 “Machine care” on page 111.
Check the current consumption of the gear motor at the Bio-
select at all times during the break-in period.
Power consumption limits
Product Description
BA-RC40_EN, 17.01.2024 www.boerger.de / www.boerger.com 65