with control unit without control unit
Minimum 8A 8A
Optimum 15A < 11A
Short-term 16A 16A
Maximum 18A 18A
* values at 400V 50Hz
NOTICE!
Risk of material damage if the limit of the current consump-
tion is exceeded!
The current consumption must not exceed the limit of 18 A. Oth-
erwise, malfunctions or even lasting damage to the wedge wire
screen and the motor may occur.
— If the brush auger is stuck in the solid matter such that the
brush auger can no longer be released / moved backwards,
the Bioselect RC separator would require manual cleaning as
described in
Ä
Chapter 6.1 “Machine care” on page 111.
Check the current consumption of the gear motor at the Bio-
select at all times during the break-in period.
Power consumption limits
Product Description