Conical pile
Install the separator in such a way that the thick matter is discharged freely
downwards, e.g. onto a conveyor belt. In order to create a conical pile, there
must be a sufficiently large difference in height between the thick matter outlet
and the ground. The volume of the conical pile is dependent on the installation
height.
— The surface must be solid, level, clean and dry.
— Position the mounting rails without subjecting them to stress.
— Compensate for any unevenness
— e.g. by using washers or shims.
— Install the Bioselect without stress on the mounting rails on the solid, stable
frame using four suitable screws, or on a solid surface using secure fixing
systems (such as heavy-duty anchors) which are suitable for the surface and
the application.
— Mobile Bioselect units must be operated on a solid surface and
be secured in place.
— Separators that are operated on a vehicle must be fixed to the
vehicle frame.
— Ensure the necessary difference in height between the thick
matter outlet (protection cover) and the ground, e.g. by posi-
tioning the outlet above a sufficiently deep pit.
— When installing special versions, check whether a supplemen-
tary operating manual is enclosed in the appendix and, if so,
follow the instructions.
Other versions
Transportation, Storage and Installation
BA-RC40_EN, 17.01.2024 www.boerger.de / www.boerger.com 77