Operation
6
CLS Pro 600 – Line and Contrast Sensor 73/108
Parameter Function / Meaning
NOTICE!The parameter is only effect-
ive when used with an ekrPro Com60
in automatic mode.
Setting Options:
off = no weighting
2 values
4 values
8 values
16 values
32 values
64 values
128 values
256 values
Pre-Adjustment:
256 values
A new comparison value must be determ-
ined as follows for the default setting of 256
values:
(Sum of the last 256 values – last value +
new value) / 256
color:
This parameter defines whether the color
comparison value should be guided.
Setting Options: ON, OFF
Pre-Adjustment: ON
contrast:
This parameter defines whether the search
contrast threshold should be guided.
NOTICE!This parameter is only active
if contrast detection /auto adjustment
is switched on.
Setting Options: ON, OFF
Pre-Adjustment: ON
edge sharpness:
This parameter defines whether the contrast
sharpness should be guided.
Setting Options: ON, OFF
Pre-Adjustment: ON
line width:
This parameter defines whether the line
width should be guided.
Setting Options: ON, OFF
Pre-Adjustment: ON