T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
21-  44 Service Manual  REFLEX  RR B,E RR B,E CC © BT Europe AB
Electrical system – 5000
Functional description
21.4.15 Hydraulic function 5
When the driver actuates the hydraulic lever R15, voltage (3.7-6.7 V or 
3.7-0.66
  V) is fed to A5, which opens the direction valves Y16/Y17 and 
sends a signal to the frequency inverter A2. Pump motor M3 starts and 
pumps oil to the extra function.
21.4.16 Cab tilt
The driver selects the function by pressing switch S44, which sends a 
signal to A5 and lamp 44 lights up. When the forks rise to the main lift 
range, switch S45 closes and a signal is sent to A5. Directional valve 
Y20 is fed voltage by A5 when cab tilting is to take place. However, the 
hydraulic lever must be activated more than 50%. Tilting is by around 
15 degrees.
If the truck has pulse counter U10, A5 receives information on the posi-
tion of the forks. At the programmed height, the cab will begin to tilt.
When the forks are lowered and reach the pre-programmed height 
again or come down to the free lift range, the cab tilts back as A5 sends 
a signal to direction valve Y21 to open. When lowering too, the hydrau
-
lic lever must be activated more than 50%.
As soon as the driver releases the hydraulic levers, the tilting and the 
forks’ lifting/lowering movement stops.
The cab can be lowered manually if the driver presses switch S44 for 
momentary mode. A5 is fed voltage and keeps direction valve Y21 
open as long as the button is depressed.
Designation Diode number
SPARE 2A 708
SPARE 2B 709
Designation Diode number
HEIGHT COUNTER 301
HEIGHT REFERENCE 302
CABIN LOWERING MANUAL 304
CABIN LIFT 305
CABIN LIFT 710
CABIN LOWERING 711