T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
38- 18 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Battery charger – 8340
Service and maintenance
Switching to the timer charger
In the event of an error so that computer controlled charging is not pos-
sible, you can temporarily switch to timer charging.
Switch the service plug, J5, located above the mother board’s con-
trol transformer.
Set J5 to its right-hand position.
Set the mains switch in position 1.
Charging starts immediately and continues for the set time, normally 12
hours. The time can be adjusted between 5 and 13 hours using poten
-
tiometer, P2. There are settings for 6 and 12 hours. The fan runs contin-
uously in service mode.
When the fault has been rectified, return J5 to its “normal position“
and P2 is set to 12 hours.