Loading...
Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 38- 15
Battery charger – 8340
Service and maintenance
Programming the API function
The register 245 shall contain the value 1 for the program to activate
the pressure monitoring function. Press * 245 * to check the content of
the register. Use the same programming procedure as for other regis
-
ters.
All calibration is completed by calculating a new checksum with * 22 *
2451 *.
38.4.5 Adjusting the charging characteristics
The charging characteristics can be adjusted by moving a strap if the
charger delivers too high or too low current at the start of charging. The
strap is located to the right of the transformer. There is one or three
straps depending on the type of charger. Next to the strap is a sign
describing how strapping shall take place.
1. Low mains voltage and high charging current.
2. Low mains voltage and low charging current.
3. Normal mains voltage and high charging current.
4. Normal mains voltage and low charging current.
https://www.forkliftpdfmanuals.com/