Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual  REFLEX RR B/E, RR B/E CC 24-  19
Electronic card – 5710
Parameter setting of all parameters
24.5.15 Parameter 22
Use this parameter to activate the brake coil function and monitoring, 
and thus achieve higher maximum travel speed.
If the machine type is changed, next time the key is switched on new 
parameters will be loaded in the frequency converters. In order for the 
new parameters to take effect, the truck must be switched off and on 
once again with the key.
24.5.16 Parameter 23
When this parameter is set to 1, this informs the truck controller that the 
fork unit is equipped with a switching valve operating two different func
-
tions. The oil flow is controlled by a valve in the large valve plate.
24.5.17 Parameter 24
When this parameter is set to 1, it is possible to stop the truck using the 
drive motor but impossible to continue driving unless the safety pedal is 
depressed.
24.5.18 Parameter 25
Use this parameter to determine the service interval of the truck. The 
buzzer sounds and code C029 is displayed when the service counter 
reaches zero. The counter shows the time that has passed since the 
last service intervention. 
If an earlier service intervention is required, simply activate this param-
eter without adjusting the time.
24.5.19 Parameter 26
When this parameter is set to 1, the cab tilt function (E 1-8) and moni-
toring are activated.
24.5.20 Parameter 27
When this parameter is set to 1, priority of the lifting function is can-
celled, i.e. the hydraulic function currently in use will continue to oper-
ate even if lifting is activated.