Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual  REFLEX RR B/E, RR B/E CC 24-  67
Electronic card – 5710
Error Codes
24.11.1 Error codes with registration
Parking brake Y1
1. Check that the switch S131 is open.
2. Disconnect the cable 64 from output 802.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 64 is intact between terminal 802 and the 
terminals in X37.
- Measure the coil on Y1 between the terminals in X37 with an 
ohmmeter. Resistance approx. 33 ohm.
- Check that cable 40 is intact from X37 to the battery negative.
3. If the fault remains, replace A5.
Code 104
Description Output 802 short circuit/breakage
Error mode Critical error
Error cause 1. Emergency switch for Y1 activated
2. Faulty wiring/valve Y1
3. Defective electronic card A5
Comments
https://www.forkliftpdfmanuals.com/