T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 22 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Parameter setting of all parameters
24.5.26 Parameter 39
Set this parameter to 1 or 2 if only three drivers/truck travel characteris-
tics will be programmed and the key is used to start the truck.
If the keypad is used and up to ten drivers/truck travel characteristics
will be programmed, set the parameter to 3 or 4. In the latter case, this
value must be programmed for each driver. See the section “Keypad”.
24.5.27 Parameters 40 to 42
Use these parameters to set the year, day and month. This setting is
used by the error code log.
24.5.28 Miscellaneous parameters
The other parameters between 10 and 42 are shown on the display and
can be programmed, however, this will not cause any change in the
software. Other parameters are fixed and cannot be reprogrammed.