T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
41-  6 Service  Manual  REFLEX RR B,E RR B,E CC © BT Europe AB
Positioning equipment – 9390
Function
41.6  Function
Measuring starts in the main lifting zone when the reference switch 
(S45) is activated and sends a signal to the electronic card (A5). The 
pulse sensor (U10) sends pulses to A5, which starts by displaying the 
programmed free lift height on the displays (A7 and A8). The forks stop 
at the first pre-programmed height when A5, via pulse sensor U10, 
reaches the correct height. The halt is initiated by A5 regulating the 
pump motor speed using A2 and valves for fork lifting and lowering. The 
driver picks up or deposits the load manually. When the driver again 
presses the hydraulic control for lifting/lowering, the forks continue to 
the next pre-programmed level. The pulse sensor has two channels, A 
and B, which relay signals with 90
°
 reciprocal ratio. This gives A5 infor-
mation on whether the forks are moving up or down. For connection, 
see Wiring Diagram, chapter 5000.
For programming the free lift height, see Setting Parameters, chapter 
5710.
The steel wire should be wrapped one turn around the measuring 
wheel and stretched taut so it does not slip.
5 mm
S45
U10
A8
A5, A2
A7
https://www.forkliftpdfmanuals.com/