EasyManua.ls Logo

BT REFLEX RR B2-3CC - Errors without indication; 38.4.7 Trouble shooting acid circulation; 38.4.8 Service measures

BT REFLEX RR B2-3CC
514 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 38- 17
Battery charger – 8340
Service and maintenance
E.76 = error in the computer board’s EE-prom.
Check that the computer board’s EE-prom is not missing or faulty.
Check that an older type of display or printer has not been connected.
E.77 = data in the computer board and mother board EE-prom is valid
but not the same.
Check that copy-over of data has been performed.
Check that the computer board does not come from another device.
Errors without indication
If the charger does not work, check that the computer board and dis-
play board are fitted correctly and are connected.
If the mains fuse blows during power up, compare the fuse value
with the chargers rated data.
Check the fuses and connections.
Check the diodes.
Check the insulation between phases and the chargers casing.
38.4.7 Trouble shooting acid circulation
With underpressure, check the hose system, nipples and couples for
leakage. If the charging plug with air connection is used, the O-rings
in the plug may be damaged.
Also check that the pump is voltage fed.
With overpressure, check the hose system for pinched hoses.
38.4.8 Service measures
NOTE
Servicing may only be carried out by qualified and authorised person-
nel.
Disconnect the charger from the mains and battery when servicing
an open charger.
Check that all cover plates are refitted and that the charger’s door is
closed and lock once serving is complete.
https://www.forkliftpdfmanuals.com/