Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual  REFLEX RR B/E, RR B/E CC 24-  47
Electronic card – 5710
Warning codes with registration
24.10  Warning codes with registration
When a warning code is registered, it is automatically displayed. Regis-
tration is made in the first of the 50 possible locations and moves previ-
ous errors one step down.
Warning codes 50–64 are either for valve, support arm brake or cable 
breakage or short circuits.
Warning codes 90-94 are either for potentiometer or cable breakage.
Only the actual function is disabled; other functions are unaffected.
Hydraulic valve Y45 engages the cab lift
1. Disconnect the cable 67 from output 710.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 67 is intact between terminal 701 and the 
terminals in X47/X54. 
- Measure the coil resistance of Y45 between the blue and black 
cables. The resistance should be approx. 90 Ohms.
- Check whether cable 40 is intact from X54 to battery minus.
2. If the fault remains, replace A5. 
Code 50
Description Output 710 short circuit/breakage
Error mode General error
Error cause 1. Faulty wiring/valve Y45
2. Defective electronic card A5
Comments
https://www.forkliftpdfmanuals.com/