T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24-  16 Service Manual  REFLEX  RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Parameter setting of all parameters
24.5.10 Parameters 15 and 16
When these parameters are set to a value >0, monitoring of the poten-
tiometers and valves for the two optional hydraulic functions is activat-
ed. The magnitude of the value determines the pressure applied for 
these functions.
24.5.11 Parameters 17 and 18
If the truck is equipped with height measurement, these two parame-
ters can be used to set the maximum lift heights. The second maximum 
height value must be equal to or larger than the first maximum height 
value. The maximum lift height is set using parameter 29.
If the truck is not equipped with height measurement U10, set this 
parameter to 0.
The parameter should be set to 0 if the truck is not equipped with height 
measurement, otherwise when using the switch for maximum lift height 
S32, the bypass of height measurement does not work.