T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 26 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Warning Codes without registration
24.8.2 Safety logic
This applies to the following functions:
X = Action-- = Function disabled
24.9 Warning Codes without registration
Action:
Function
K10
opens
Y1
activated
Reversing
with M1
Steering
disabled
Function at A2
halted
Emergency switch X X -- --
Key X X -- X --
Steering error X X
Error at A1 X -- --
Error at A2 X (and el. valves off)
Error at A5 X X -- X --
Code 3
Description Shock sensor activated by TLS
Error type Travel speed reduced to inching speed
Error causes 1. Truck collision
2.
3.
4.
Note Enter the reset code (11111) using the keypad
Code 4
Description Truck has been immobilised via programming of
the TLS
Error type Travel speed reduced to inching speed
Error causes 1. Stop code entered in the TLS.
2.
3.
4.
Note Enter the reset code via the TLS or the service
code
https://www.forkliftpdfmanuals.com/