data(p. 77) for more information). Examples of settings that force the data logger program to
recompile:
l
IP address
l
IP default gateway
l
Subnet mask
l
PPP interface
l
PPP dial string
l
PPP dial response
l
Baud rate change on control ports
l
Maximum number of TLS server connections
l
PakBus encryption key
l
PakBus/TCP server port
l
HTTP service port
l
FTP service port
l
PakBus/TCP service port
l
PakBus/TCP client connections
l
Communications allocation
23.1 DataTableInfo table system information
The DataTableInfo table is automatically created when a program produces other data tables.
View the DataTableInfo table by connecting the data logger to your computer (see Making the
software connection(p. 70) for more information).
Most fields in the DataTableInfo table are read only and of a numeric data type unless noted.
Error counters (for example SkippedRecord) may be reset to 0 for troubleshooting purposes.
l
LoggerNet users, select DataTableInfo from the Table Monitor list.
l
PC400 users, click the Monitor Data tab and add the DataTableInfo to display it.
23.1.1 DataFillDays
Reports the time required to fill a data table.
23.1.2 DataRecordSize
Reports the number of records allocated to a data table.
23.1.3 DataTableName
Reports the names of data tables. Array elements are in the order the data tables are declared in
the CRBasic program.
l
String data type
23. Information tables and settings (advanced)203