23.3.59.10 CellPwrRepeat
Specifies the interval in minutes to power on the cellular interface following the first time of the
day that the data logger powers on its cellular interface. For example usage, see CellPwrDuration.
l
Long data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: Cellular > Repeat cycle
23.3.59.11 CellPwrStartTime
Specifies time of day in minutes when the data logger will first enable the cellular interface.
Examples:
l
15 = 00:15 ’15 minutes after midnight
l
180 = 03:00 ‘3:00 am
l
1380 = 23:00 ’11:00 pm
l
1440 = Always On
For example usage, see CellPwrDuration.
l
Long data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: Cellular > Start (power-on) time
23.3.59.12 CellRSRQ
CellECIO
Specifies the signal quality of the modem. For 3G, this is ECIO (Energy to Interference Ratio). For
4G, this is RSRQ (Reference Signal Received Quality). Updated when queried by your data logger
support software or a program. Ranges expected for Signal Quality for 3G/4G:
Excellent: 0 to -6 (3G), >-9 (4G)
Good: -7 to -10 (3G), -9 to -12 (4G)
Fair to Poor: -11 to -20 (3G), -13 or less (4G)
l
Float data type
l
Read only
23. Information tables and settings (advanced)226

Table of Contents

Other manuals for Campbell CR310

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR310 and is the answer not in the manual?

Campbell CR310 Specifications

General IconGeneral
BrandCampbell
ModelCR310
CategoryData Loggers
LanguageEnglish

Related product manuals