12.2.2.2 Set up LoggerNet
The LoggerNet Network Map is configured from the LoggerNet Setup screen.
NOTE:
Setup has two options, EZ (simplified) and Standard. Click on the View menu at the top of the
Setup screen, and select Standard view.
From the LoggerNet toolbar, click Main > Setup and configure the Network Map as described in
the following steps:
1. Select Add Root > IPPort.
2. Select PakBusPort.
3. Add a data logger to the PakBusPort.
4. Select the IPPort in the Network Map. Enter the CR300-CELL IP address and port number.
The IP address and port number are input in the Internet IP Address field separated by a
colon. Preceding zeros are not entered in the Internet IP Address (for example,
070.218.074.247 is entered as 70.218.74.247). The default port number is 6785.
5. For PakBus data loggers, leave the default settings for the PakBusPort. PakBus Port Always
Open should not be checked. If a TCP Password is used, enter it.
12. Cellular communications option48