6. For PakBus data loggers, select the data logger in the Network Map and set the PakBus
Address to match that of the data logger (default address in the data logger is 1). If a
PakBus Encryption Key was entered during data logger setup, also enter it here. Click Apply
to save the changes.
12.2.2.3 Test the connection
Use the Connect screen to test the connection. Click on the appropriate station and click Connect
to initiate a call to the data logger. The data logger must have 12 V power.
TIP:
The connection time is subject to many external factors. It is often less than 30 seconds but
could be up to 15 minutes. Be patient.
If the connection is successful, the connectors icon at the bottom of the screen will come
together and clock information from the data logger will be displayed in the Station Date/Time
field. If the connection fails, a Communications Failure message will be displayed.