SECTION 4
4-34
BATTERIES - LEVEL - CHARGE CHECK
AND CLAMPS TIGHTENING
Batteries are stored on the right front side of the
machine.
The batteries (1) are accessible though the engine
hood (2).
CHECKING THE ELECTROLYTE LEVEL
Remove the caps (1).
When the undercaps (2) are present:
- electrolyte level should reach base of these.
Without undercaps:
- electrolyte level should be 10 - 15 mm (0.39-
0.59 in) above top of plates.
If necessary, top up with distilled water.
Retighten the caps (1).
S CAUTION S
Batteries give off explosive gases.
Never handle naked flames and unshielded light
sources near batteries, never smoke.
Battery acid is toxic and corrosive.
Avoid any contact with the skin, mouth, eyes and
clothing. Avoid spilling battery acid. Avoid inhaling
the vapours.
Wear acid-proof gloves, firm protective clothing and
goggles.
If the skin is splashed with acid, rinse thoroughly
with water and consult a doctor.
Never wear metal necklaces, bracelets or watch-
straps when working on the battery. The metal parts
may induce a short circuit resulting in burns.
If the eyes are splashed with acid, rinse thoroughly
with running water and consult a doctor immedi-
ately.
Never set tools down on the battery. They may
induce a short circuit, causing irreparable damage
to the battery and injuring persons.