71-14
Cisco ASA 5500 Series Configuration Guide using ASDM
OL-20339-01
Chapter 71 Configuring Logging
Configuring Logging
The selected logging destination for a filter appears at the top.
Note Using a severity level of zero is not recommended.
Adding or Editing a Message Class and Severity Filter
To add or edit a message class and severity level for filtering messages, perform the following steps:
Step 1 Choose the event class from the drop-down list. Available event classes change according to the device
mode that you are using.
Step 2 Choose the level of logging messages from the drop-down list. Severity levels include the following:
• Emergency (level 0, system is unusable)
• Alert (level 1, immediate action is needed)
• Critical (level 2, critical conditions)
• Error (level 3, error conditions)
• Warning (level 4, warning conditions)
• Notification (level 5, normal but significant conditions)
• Informational (level 6, informational messages only)
• Debugging (level 7, debugging messages only)
Step 3 Click OK when you are done making selections.
Note Using a severity level of zero is not recommended.