B-278 Cisco 7000 Hardware Installation and Maintenance
Interface Processor LEDs
MIP LEDs
After system initialization, the enabled LED (shown in Figure B-14), which is present on all
interface processors, turns on to indicate that the MIP has been enabled for operation.
Figure B-14 MIP LEDs
The following conditions must be met before the MIP is enabled:
• The MIP contains a valid microcode version that has successfully been downloaded.
• The MIP is correctly connected to the backplane and receiving power.
• The CxBus recognizes the MIP card.
If any of these conditions is not met, or if the initialization fails for other reasons, the enabled LED
does not turn on.
The three LEDs above each MIP port indicate the following:
• Local alarm—Indicates a loss of signal, a loss of frame, or unavailability due to excessive errors.
• Remote alarm—Indicates a remote alarm is received from the remote end due to a local alarm at
the remote end.
• Loop—Indicates controller local loopback.
H2279
ENABLED
LOCAL ALARM
REMOTE ALARM
LOOP

Table of Contents

Other manuals for Cisco 7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 7000 and is the answer not in the manual?

Cisco 7000 Specifications

General IconGeneral
Product TypeSwitch
Model7000
CategorySwitch
PortsVaries by configuration
Power SupplyRedundant power supplies supported
ManagementSNMP, CLI

Related product manuals