10-22
Catalyst 2950 Desktop Switch Software Configuration Guide
78-11380-03
Chapter 10 Configuring the Switch Ports
Configuring SPAN
Configuring SPAN
This section describes how to configure SPAN on your switch and contains this information:
SPAN Configuration Guidelines, page 10-22
CreatingaSPANSessionandSpecifyingPortstoMonitor,page10-23
Removing Ports from a SPAN Session, page 10-24
Displaying SPAN Status, page 10-25
SPAN Configuration Guidelines
Follow these guidelines when configuring SPAN:
SPAN is disabled by default.
Use a network analyzer to monitor ports.
Only one SPAN sessions can be active on a switch at the same time.
The destination port cannot be a source port; a source port cannot be a destination port.
You can have only one destination port.
An EtherChannel port can be a SPAN source port; it cannot be a SPAN destination port.
For a SPAN source port, you can monitor transmitted and received traffic for a single port or for a
series or range of ports.
When you configure a switch port as a SPAN destination port, it is no longer a normal switch port;
only monitored traffic passes through the SPAN destination port.
When you specify a single source port and do not specify a traffic type (Tx, Rx, or both), both is the
default.
You can configure a disabled port to be a source or destination port, but the SPAN function does not
start until the destination port and at least one source port is enabled.
The no monitor session session_number global configuration command removes a source or
destination port from the SPAN session from the SPAN session. If you do not specify any options
following the no monitor session session_number command, the entire SPAN session is removed.
A SPAN destination port never participates in any VLAN spanning tree. SPAN does include BPDUs
in the monitored traffic, so any spanning-tree BPDUs received on the SPAN destination port for a
SPAN session were copied from the SPAN source ports.
When SPAN is enabled, configuration changes have these results:
If you change the VLAN configuration of a destination port, the change is not effective until
SPAN is disabled.
If you disable all source ports or the destination port, the SPAN function stops until both a
source and destination port are enabled.

Table of Contents

Other manuals for Cisco Catalyst 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2950 and is the answer not in the manual?

Cisco Catalyst 2950 Specifications

General IconGeneral
Forwarding Bandwidth8.8 Gbps
Switching Capacity13.6 Gbps
Forwarding Rate6.6 Mpps
Weight3.6 kg
RAM16 MB
Flash Memory8 MB
Operating Humidity10% to 85% non-condensing
Uplink Ports2 x 10/100/1000Base-T
Dimensions4.4 cm x 44.5 cm x 24.2 cm
Remote Management ProtocolSNMP, Telnet, HTTP
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p
Status Indicatorssystem
Operating Temperature0 to 45°C
Ports24 x 10/100 Ethernet ports
MAC Address Table Size8, 192 entries
Power SupplyInternal 100-240V AC, 50-60Hz

Related product manuals