Appendix B System Messages
Error Messages and Recovery Procedures
Error Message CMP-5-REMOVE The Device is removed from the cluster (Cluster
Name:[chars])
Explanation
The message means that the device is removed from the cluster: [chars] is the cluster
name.
Recommended Action No action is required.
Environment Messages
This section contains the Environment error messages.
Error Message ENVIRONMENT-2-FAN_FAULT
Explanation
This message means that an internal fan fault is detected.
Action Either check the switch itself, or use the show env privileged EXEC command to determine
if a fan on the switch has failed. The Catalyst 2950 switch can operate normally with one failed fan.
Replace the switch at your convenience.
GigaStack Messages
This section contains the GigaStack error messages.
Error Message GIGASTACK-3-INIT_FAILURE
Explanation
This message means that the Gigastack GBIC failed POST.
Recommended Action Remove the Gigastack GBIC and re-insert it into the GBIC slot.
Error Message GIGASTACK-6-LOOP_BROKEN
Explanation
This message means that a loop formed by GigaStack modules is broken because of link
loss. Link 2 of the Master Loop Breaker is re-enabled to replace the broken line.
Recommended Action No action is required.
Error Message GIGASTACK-6-LOOP_DETECTED
Explanation
This message means that a loop has been detected in the GigaStack, and that this
GigaStack GBIC is selected as the Master Loop Breaker. Link 2 of this GigaStack GBIC is disabled
to break the loop.
Recommended Action No action is required.