EasyManuals Logo

Cisco IE-5000 User Manual

Cisco IE-5000
1066 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #509 background imageLoading...
Page #509 background image
505
Configuring UDLD
How to Configure UDLD
If you enable aggressive mode when all the neighbors of a port have aged out either in the advertisement or in the
detection phase, UDLD restarts the link-up sequence to resynchronize with any potentially out-of-sync neighbor. UDLD
shuts down the port if, after the fast train of messages, the link state is still undetermined.
Figure 71 UDLD Detection of a Unidirectional Link
Default UDLD Settings
How to Configure UDLD
Enabling UDLD Globally
Follow these steps to enable UDLD in the aggressive or normal mode and to set the configurable message timer on all
fiber-optic ports on the switch:
TX
TX
RX
RX
Switch A
Switch B
Switch B successfully
receives traffic from
Switch A on this port.
98648
However, Switch A does not receive traffic
from Switch B on the same port. If UDLD
is in aggressive mode, it detects the
problem and disables the port. If UDLD is
in normal mode, the logical link is
considered undetermined, and UDLD
does not disable the interface.
Feature Default Setting
UDLD global enable state Globally disabled
UDLD per-port enable state for fiber-optic media Disabled on all Ethernet fiber-optic ports
UDLD per-port enable state for twisted-pair (copper) media Disabled on all Ethernet 10/100 and 1000BASE-TX ports
UDLD aggressive mode Disabled

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco IE-5000 and is the answer not in the manual?

Cisco IE-5000 Specifications

General IconGeneral
ModelIE-5000
CategoryIndustrial Ethernet Switch
Switching Capacity128 Gbps
Forwarding Rate95.2 Mpps
MAC Address Table Size16, 000 entries
Ports16 or 24 10/100/1000 ports
Uplink Ports4 SFP ports
Operating Temperature-40°C to 70°C
Power SupplyDual redundant power supplies
MountingDIN rail
ManagementWeb GUI, CLI, SNMP
Input Voltage24 VDC or 110/220 VAC
LayerLayer 2/3
Jumbo Frame SupportUp to 9216 bytes