EasyManuals Logo

Datalogic Magellan 3300HSi User Manual

Datalogic Magellan 3300HSi
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #151 background imageLoading...
Page #151 background image
Product Reference Guide 143
QR Code (continued)
QR Code Length 1, Length 2 Programming Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
3. Turn to Appendix C, and scan the four digits (zero-padded) representing
the length.
NOTE
For 2d Code labels, only the data characters are included in
the length calculations.
Any value set higher than 2710 will be considered to be
2710.
Scan the END bar code.
START / END
PROGRAMMING bar codes
DEFAULT SETTING FOR THIS FEATURE: 0001
Set Length 1
Set Length 2
DEFAULT SETTING FOR THIS FEATURE: 2710

Table of Contents

Other manuals for Datalogic Magellan 3300HSi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 3300HSi and is the answer not in the manual?

Datalogic Magellan 3300HSi Specifications

General IconGeneral
Scanner type1D
Decoding standardsGS1, MicroPDF417, PDF417
Optical sensor resolution1280 pixels
Light levels (direct sunlight)0 - 86100 lx
Dimensions (WxDxH)152 x 87 x 152 mm
Power consumption (active)9.9 W
Standard interfacesUSB, RS-232
Input voltage90 - 264 V
Power requirements47 - 63 Hz
Power consumption (standby)2 W
CertificationRoHS, EN 60825-1, IEC 60825, IEC 60825-1
Product colorStainless steel
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Weight790 g

Related product manuals