104 Magellan™ 3300HSI
GS1 DataBar Omnidirectional / Stacked Omnidirectional
The following options apply to the GS1 DataBar Omnidirectional symbology.
Disable/Enable GS1 DataBar Omnidirectional
When this feature is disabled, the scanner will not read GS1 DataBar Omnidirec-
tional bar codes.
UCC/EAN 128 Emulation
When enabled, GS1 DataBar Omnidirectional bar codes will be translated to the
UCC/EAN 128 label data format.
START / END
PROGRAMMING bar codes
Disable GS1 DataBar Omnidirectional
DEFAULT
Enable GS1 DataBar Omnidirectional
START / END
PROGRAMMING bar codes
Disable UCC/EAN 128 Emulation
DEFAULT
Enable UCC/EAN 128 Emulation