30 Magellan™ 3300HSI
Good Read: When to Indicate
This feature specifies when the scanner will provide indication (beep and/or
flash its green LED) upon successfully reading a bar code. Choices are:
Good Read = Indicate after decode
Good Read = Indicate after transmit
Good Read = Indicate after CTS
goes inactive, then activ
NOTE
This option (Indicate after CTS goes inactive, then
ac
tive), which uses CTS, is only valid for RS-232
interfaces.
e
START / END
PROGRAMMING bar codes
After Decode
DEFAULT
After Transmit
After CTS goes inactive, then active
³

Table of Contents

Other manuals for Datalogic Magellan 3300HSi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 3300HSi and is the answer not in the manual?

Datalogic Magellan 3300HSi Specifications

General IconGeneral
Scanner type1D
Decoding standardsGS1, MicroPDF417, PDF417
Optical sensor resolution1280 pixels
Light levels (direct sunlight)0 - 86100 lx
Dimensions (WxDxH)152 x 87 x 152 mm
Power consumption (active)9.9 W
Standard interfacesUSB, RS-232
Input voltage90 - 264 V
Power requirements47 - 63 Hz
Power consumption (standby)2 W
CertificationRoHS, EN 60825-1, IEC 60825, IEC 60825-1
Product colorStainless steel
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Weight790 g