Product Reference Guide 49
RS-232 Interface Features (continued)
Hardware Flow Control
Disable Hardware Control —
The scanner transmits to the host regardless of any
activity on the CTS line.
Enable CTS Flow Control —
The CTS signal controls transmission of data to the
host.
Enable CTS Scan Control —
The CTS line must be active for the scanner to read and
transmit data. While the CTS line is inactive, the scanner remains in a host-dis-
abled state; following a successful label transmission, the CTS signal must
transition to inactive and then to active to enable scanning for the next label.
START / END
PROGRAMMING bar codes
Disable Hardware Control
DEFAULT
Enable CTS Flow Control
Enable CTS Scan Control