68 Magellan™ 3300HSI
USB-OEM Interface Features
USB-OEM Device usage
The USB-OEM protocol allows for the scanner to be identified as one of two dif-
ferent types of bar code scanners. Depending on what other scanners you may
already have connected to a USB-OEM POS, you may need to change this setting
to enable all devices to communicate. Options are:
Table Top Scanner
Handheld Scanner
START / END
PROGRAMMING bar codes
Configure as Table Top Scanner
DEFAULT
Configure as Handheld Scanner
IBM
IBM Transmit Labels in Code 39 Format
This feature enables/disables scanner's ability to set a symbology identifier for
a specified label to Code 39 before transmitting that label data to an IBM host.
This applies to: Code 128, Codabar and Code 93 for USB-OEM; Code 128, Cod-
abar and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B.
START / END
PROGRAMMING bar codes
Disable Convert to Code 39
DEFAULT
Enable Convert to Code 39