196 Magellan™ 3300HSi
Datalogic Handheld Data Format Requirements
The following sections describe label transmission formats that are typically
observed in factory configurations of Datalogic handheld scanners.
RSS-14
Prefix must be ASCII characters ‘R4’
Check character must be included in label
Application identifier “01” must follow the prefix and preceed the base
label
Label length excluding prefix characters must be 16 characters.
Example: ‘R40101044123456789’
RSS Expanded
Prefix must be ASCII characters ‘R4’
Check character must be included in label
UPC-A
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Prefix must be an ASCII character 'A' - total length including prefix must
be 13.
Example: 'A060992011187'.
UPC-A with 2-Digit Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'A' - total length including prefix must
be 15.
Example: 'A06099201118712'.
UPC-A with 5-Digit Supplemental
Number system must be included in label data
Check digit must be included in label data and is assumed to be correct
Prefix must be an ASCII character 'A' - total length including prefix must
be 18
Example: 'A06099201118712345'
UPC-A with Code 128 Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'A' - total length including prefix must
be greater or equal to 19 Code 128 Supplemental codes are variable
length having a minimum of 2 data characters).
Characters immediately following base label must be of the form '8100',
'8101' or '8102'.
Example: 'A0609920111878100000951'.