Maintenance
DeLaval voluntary milking system VMS
94897201.pdf2007-12-18
Vacuum pump
- Check that the vacuum level is 44±1 kPa.
Vacuum gauges are usually positioned in
the machine room and at the milking
station. The vacuum level is also
displayed on the touch screen.
If necessary, see the service chapter in the
manual that came with the product.
Atlas Copco SF4 Full-feature
compressor
- Check that the air pressure is between
7-8 bar.
- Make sure that the ventilation (or heating)
is sufficient to maintain ambient
temperature between 10 and 30 °C.
- Check the dew point gauge.
- Drain the condensed water manually.
The compressor should never be exposed
to temperatures below 0 (zero).
The ambient temperature of the compressor
should not rise above 40 °C.
————————————————————
Warning: Do not perform service on the
compressor without first consulting the
handbook.
————————————————————