Cleaning of teat preparation cup
1. On the touch screen, press the VMS,
then Teatcleaner Service button.
2. Press the button Cleaner Park Weight
twice, then pull out the teat preparation cup.
3. Clean the teat preparation cup and its
tube using water, mild cleaning detergent,
and a brush. Check the tube for damage.
4. Flush with water to remove the cleaning
detergent.
FG
Teat preparation cup home position
Lid
5. Flush the home position, including the lid.
6. Retract the teat preparation cup by
pressing Cleaner Park Weight.
7. Check that the cord between the
retraction cylinder and the pulley is tight and
not damaged or worn.
8. Press the Close Teatcleaner Serv and
Maint button to close the window.
Cleaning of end effector
————————————————————
Warning: Never use fingers when cleaning
the end effector.
————————————————————
————————————————————
Caution: Do not use high-pressure devices
when cleaning the gripper. Penetrating
water might destroy the gripper interior.
————————————————————