Maintenance
DeLaval voluntary milking system VMS
94897201.pdf2007-12-18
Cleaning detergent
- Make sure that the cleaning detergent
used for system cleaning is not exhausted.
- Check that the cleaning detergent is being
employed as it should be.
Daily maintenance
As a recommendation, the milking station
should be cleaned three times a day to
avoid contamination between the cows.
Especially important items below are:
Magazine, teatcups and milk tubes
Teat preparation module
Feeding module
Stall and floor
Cleaning equipment
One or two brushes
One or two buckets
A piece of pneumatic hose (6 mm in
diameter)
A screwdriver with a flat blade
Mild cleaning detergent
Water hose
Preparations for working safely
Before cleaning the milking station, do
the following:
FG
FG
Work modeService mode
1. Put the milking station in manual mode
and park the multi-purpose arm.
2. Deactivate the multi-purpose arm by
setting the service switch to service mode.
3. Close both gates of the station to prevent
cows from entering.
109(198)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DeLaval VMS 2008 and is the answer not in the manual?

DeLaval VMS 2008 Specifications

General IconGeneral
BrandDeLaval
ModelVMS 2008
CategoryFarm Equipment
LanguageEnglish

Related product manuals