Maintenance
DeLaval voluntary milking system VMS
94897201.pdf2007-12-18
Hydraulic pump unit
Oil filter indicator
Temperature/Oil level indicator
Hydraulic pump unit
Max. oil level
60 °C = min. oil level
Oil cap
- Check the oil temperature of the hydraulic
pump unit. Depending on the ambient
temperature, normal temperature of the
oil should be between 30-50 °C. If the
temperature increases more than 60 °C,
an alarm will be issued and the pump will
stop.
The ambient temperature of the hydraulic
pump unit should not rise above 40 °C.
- Check the oil level on the indicator. Oil
level should not decrease below the
minimum level. Minimum oil mark is
located at the same level as 60 °C. If
necessary, open the oil cap and fill the
pump unit with oil.
————————————————————
Warning: The multi-purpose arm is driven
by hydraulic oil. Avoid skin contact when
handling oil. Repeated contact with the oil
may cause severe skin injury. Keep away
from children and animals.
————————————————————
————————————————————
Caution: Only use DeLaval hydraulic
synthetic oil. Mixing this oil with hydraulic
standard oil or any other type of oil may
damage the system.
————————————————————
————————————————————
Caution: When filling the hydraulic pump
unit with oil, ensure that no dirt or particles
enter into the unit.
————————————————————
108(198)