Safety precautions
DeLaval voluntary milking system VMS
94897201.pdf2007-12-18
multi-purpose arm can still move.
- If service switch is in working mode.
- If service switch is in service mode and
the safety button is pressed, and some
operation is started.
————————————————————
cd29802
Hydraulic pump unit
Hydraulic accumulator
Warning: The VMS system contains one
accumulator on the upper part of the arm
(bracket). Note that the multi-purpose arm
can move even though the hydraulic pump
unit has been shut down. Turn off the
hydraulic pump unit and depressurise the
accumulator on the bracket before
performing service or making repairs.
————————————————————
————————————————————
Warning: For additional safety, deactivate
the multi-purpose arm. Always set the
service switch to service mode when
carrying out external cleaning or when
performing other kind of maintenance work
such as exchanging liners.
————————————————————