Operation
DeLaval voluntary milking system VMS
94897201.pdf2007-12-18
Hydraulic pump
unit
60 °C = min.
oil level
Max oil
level
Oil cap
Oil temperature/Oil level
indicator
Oil level alarm
Check the oil level on the indicator. The oil
level should not decrease below the
minimum level. Minimum oil mark is located
at the same level as 60 °C. If necessary,
open the oil cap and fill the pump unit with
hydraulic oil recommended by DeLaval.
————————————————————
Warning: The multi-purpose arm is driven
by hydraulic oil. Avoid skin contact when
handling oil. Repeated contact with the oil
may cause severe skin injury. Keep away
from children and animals.
————————————————————
————————————————————
Caution: Only use DeLaval synthetic oil.
Mixing this oil with hydraulic standard oil or
any other type of oil may damage the
system.
————————————————————
————————————————————
Caution: When filling the hydraulic pump
unit with oil, ensure that no dirt or particles
enter into the unit.
————————————————————
53(198)