Chapter 4 Parameters|
4-60 Revision Jan. 2009, 06EE, SW--PW V1.12/CTL V2.12
02.01 Source of First Operation Command
Factory Setting: 1
Settings 0 Digital keypad (Digital keypad is optional)
1 External terminals. Keypad STOP/RESET enabled.
2 External terminals. Keypad STOP/RESET disabled.
3 RS-485 (RJ-45)/USB communication. Keypad STOP/RESET
enabled.
4 RS-485 (RJ-45)/USB communication. Keypad STOP/RESET
disabled.
5 CANopen communication. Keypad STOP/RESET disabled.
The factory setting for source of first operation command is 1. (digital keypad is optional.)
When the AC motor drive is controlled by external terminal, please refer to Pr.02.05/Pr.04.04
for details.
02.10
Combination of the First and Second Master Frequency
Command
Factory Setting: 0
Settings 0 First Master Frequency Command Only
1 First Master Frequency + Second Master Frequency
2 First Master Frequency - Second Master Frequency
It can be used to add or subtract the first frequency set in Pr.02.00 and the second frequency
set in Pr.02.09 to meet the customers’ application. For example, if the master frequency is the
first frequency, speed source, controlled by ACI (DC 4~20mA) and the second frequency,
press source, is controlled by AVI(DC 0~+10V). These two frequencies can be added or
subtracted by Pr.02.10.
Related parameters: Pr.02.00(Source of First Master Frequency Command) and
Pr.02.09(Source of Second Frequency Command ).
02.02 Stop Method
Factory Setting: 0
Settings 0 STOP: ramp to stop E.F.: coast to stop
1 STOP: coast to stop E.F.: coast to stop
2 STOP: ramp to stop E.F.: ramp to stop
3 STOP: coast to stop E.F.: ramp to stop