Chapter 4 Parameters|
Revision Jan. 2009, 06EE, SW--PW V1.12/CTL V2.12 4-25
Parameter Explanation Settings
Factory
Setting
Custome
r
09.09
Communication
Protocol for USB
Card
0: 7,N,2 for ASCII
1: 7,E,1 for ASCII
2: 7,O,1 for ASCII
3: 8,N,2 for RTU
4: 8,E,1 for RTU
5: 8,O,1 for RTU
1
09.09
Communication
Protocol for USB
Card
6: 8,N,1 (Modbus, RTU)
7: 8,E,2 (Modbus, RTU)
8: 8,O,2 (Modbus, RTU)
9: 7,N,1 (Modbus, ASCII)
10: 7,E,2 (Modbus, ASCII)
11: 7,O,2 (Modbus, ASCII)
09.10
Transmission Fault
Treatment for USB
Card
0: Warn and keep operating
1: Warn and ramp to stop
2: Warn and coast to stop
3: No warning and keep operating
0
09.11
Time-out Detection
for USB Card
0.1 ~ 120.0 seconds
0.0: Disable
0.0
09.12
COM port for PLC
Communication
(NOT for VFD*E*C
models)
0: RS485
1: USB card
0
Group 10 PID Control Parameters
Parameter Explanation Settings
Factory
Setting
Custome
r
0: Disable PID operation
1: Keypad (based on Pr.02.00)
2: 0 to +10V from AVI
3: 4 to 20mA from ACI or 0 to +10V from
AVI2
10.00
PID Set Point
Selection
4: PID set point (Pr.10.11)
0