Chapter 4 Parameters|
4-24 Revision Jan. 2009, 06EE, SW--PW V1.12/CTL V2.12
Parameter Explanation Settings
Factory
Setting
Custome
r
0: Warn and keep operating
1: Warn and ramp to stop
2: Warn and coast to stop
09.02
Transmission Fault
Treatment
3: No warning and keep operating
3
09.03 Time-out Detection
0.1 ~ 120.0 seconds
0.0: Disable
0.0
0: 7,N,2 (Modbus, ASCII)
1: 7,E,1 (Modbus, ASCII)
2: 7,O,1 (Modbus, ASCII)
3: 8,N,2 (Modbus, RTU)
4: 8,E,1 (Modbus, RTU)
09.04
Communication
Protocol
5: 8,O,1 (Modbus, RTU)
0
6: 8,N,1 (Modbus, RTU)
7: 8,E,2 (Modbus, RTU)
8: 8,O,2 (Modbus, RTU)
9: 7,N,1 (Modbus, ASCII)
10: 7,E,2 (Modbus, ASCII)
11: 7,O,2 (Modbus, ASCII)
09.05 Reserved
09.06 Reserved
09.07
Response Delay
Time
0 ~ 200 (unit: 2ms)
1
09.08
Transmission Speed
for USB Card
0: Baud rate 4800 bps
1: Baud rate 9600 bps
2: Baud rate 19200 bps
3: Baud rate 38400 bps
4: Baud rate 57600 bps
2