Chapter 4 Parameters|
4-102 Revision Jan. 2009, 06EE, SW--PW V1.12/CTL V2.12
01011 0
Weights
Bit
0=external terminal
1=internal terminal
MI1
MI2
MI3
MI4
MI5
MI6
When extension card is installed, the number of the multi-function input terminals will increase
according to the extension card. The maximum number of the multi-function input terminals is
shown as follows.
12
3
4
5
0
MI1
MI2
MI3
MI4
MI5
MI6
Weights
Bit
78
9
10
11
6
MI7
MI8
MI9
MI10
MI11
MI12
0=external terminal
1=internal terminal
This parameter is used to set the internal terminal action via keypad(optional), communication
or PLC.
For standard AC motor drive (without extension card), the multi-function input terminals are
MI1 to MI6 as shown in the following.
12345 0
0=set internal terminal to be OFF
1= ONset internal terminal to be
MI1
MI2
MI3
MI4
MI5
MI6
Weights
Bit
04.28
Internal Terminal Status
Unit: 1
Settings
0 to 4095
Factory Setting: 0