Chapter 4 Parameters|
4-20 Revision Jan. 2009, 06EE, SW--PW V1.12/CTL V2.12
Parameter Explanation Settings
Factory
Setting
Custome
r
07.11
Accumulative Motor
Operation Time
(Day)
0 to 65535 Day 0
07.12
Motor PTC
Overheat Protection
0: Disable
1: Enable
0
07.13
Input Debouncing
Time of the PTC
Protection
0~9999(*2ms) 100
07.14
Motor PTC
Overheat Protection
Level
0.1~10.0V 2.4
07.15
Motor PTC
Overheat Warning
Level
0.1~10.0V 1.2
07.16
Motor PTC
Overheat Reset
Delta Level
0.1~5.0V 0.6
07.17
Treatment of the
Motor PTC
Overheat
0: Warn and RAMP to stop
1: Warn and COAST to stop
2: Warn and keep running
0
07.18
Motor Rated Current
(Motor 1)
30 %FLA to 120% FLA FLA
07.19
Motor No-Load
Current (Motor 1)
0%FLA to 99% FLA 0.4*FLA
07.20
Torque
Compensation
(Motor 1)
0.0 to 10.0 0.0
07.21
Slip Compensation
(Used without PG)
(Motor 1)
0.00 to 10.00 0.00
07.22
Motor Line-to-line
Resistance R1
(Motor 1)
0~65535 mΩ
0
07.23
Motor Rated Slip
(Motor 1)
0.00 to 20.00 Hz 3.00
07.24
Motor Pole Number
(Motor 1)
2 to 10 4
07.25
Motor Rated Current
(Motor 2)
30 %FLA to 120% FLA FLA

Table of Contents