SIRIUS
®
TECHNICAL REFERENCE MANUAL
Adverse environmental conditions are Moisture or high humidity Dust, flammable gases, fumes
or dissolver Thunderstorm or thunderstorm conditions (except assembly PNA) Electrostatic
fields, etc.
The measurement category can be adjusted depending on the module configuration.
Any other use than described above may damage your system and is attended with dangers like
short-circuiting, fire or electric shocks.
The whole system must not be changed, rebuilt or opened.
DO NOT operate damaged equipment: Whenever it is possible that the safety protection
features built into this product have been impaired, either through physical damage, excessive
moisture, or any other reason, REMOVE POWER and do not use the product until the safe
operation can be verified by service-trained personnel. If necessary, return the product to the
Dewesoft sales and service office for service and repair to ensure that safety features are
maintained.
If you assume a more riskless use is not provided anymore, the system has to be rendered
inoperative and should be protected against inadvertent operation. It is assumed that a more
riskless operation is not possible anymore if the system is damaged obviously or causes strange
noises. the system does not work anymore. the system has been exposed to long storage in
adverse environments. the system has been exposed to heavy shipment strain.
Warranty void if damages caused by disregarding this manual. For consequential damages, NO
liability will be assumed!
Warranty void if damage to property or persons caused by improper use or disregarding the
safety instructions.
Unauthorized changing or rebuilding the system is prohibited due to safety and permission
reasons (CE).
Be careful with voltages >25 VAC or >35 VDC! These voltages are already high enough in order to
get a perilous electric shock by touching the wiring.
The product heats during operation. Make sure there is adequate ventilation. Ventilation slots
must not be covered!
Only fuses of the specified type and nominal current may be used. The use of patched fuses is
prohibited.
Prevent using metal bare wires! Risk of short circuit and fire hazard!
DO NOT use the system before, during or shortly after a thunderstorm (risk of lightning and high
energy over-voltage). An advanced range of applications under certain conditions is allowed with
therefore designed products only. For details please refer to the specifications.
Make sure that your hands, shoes, clothes, the floor, the system or measuring leads, integrated
circuits and so on, are dry.
DO NOT use the system in rooms with flammable gases, fumes or dust or in adverse
environmental conditions.
Avoid operation in the immediate vicinity of high magnetic or electromagnetic fields,
transmitting antennas or high-frequency generators, for exact values please refer to enclosed
specifications.
Use measurement leads or measurement accessories aligned with the specification of the
system only. Fire hazard in case of overload!
Do not switch on the system after transporting it from a cold into a warm room and vice versa.
The thereby created condensation may damage your system. Acclimatize the system unpowered
to room temperature.
Do not disassemble the system! There is a high risk of getting a perilous electric shock.
Capacitors still might be charged, even if the system has been removed from the power supply.
SIRIUS
®
V20-1 332 / 336

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DEWESOFT SIRIUS Series and is the answer not in the manual?

DEWESOFT SIRIUS Series Specifications

General IconGeneral
CategoryData Loggers
ManufacturerDEWESOFT
SeriesSIRIUS
Resolution24-bit
InterfaceUSB, EtherCAT
SoftwareDEWESoft X
ChannelsExpandable
Sampling RateUp to 200 kS/s per channel
Input TypesVoltage, Current, IEPE, Strain, Thermocouple, RTD, Resistance, Digital, Counter
Input Voltage Range±10 V, ±200 V
IsolationChannel-to-channel and channel-to-ground
ConnectivityEthernet, USB
Operating Temperature-10 °C to +50 °C
Storage Temperature-20 °C to +70 °C
Power Supply10 to 30 V DC
DimensionsVaries depending on module configuration
WeightVaries depending on module configuration
Analog InputsYes, depending on module configuration