3.1 General Information
3.1a How To Enter Maintenance Mode
When powered on, the scale always gets into Operation Mode.
WEIGHT UNIT WEIGHT QUANTITY
0 . 0 0 0 . 0
ZERO NET 1 2 3 RECO IN OUT 1 2 3 4 5 6 7 8
(SCALE) JOB MODULE
STABLE KG INSUFF MEMORY
1. Change to Maintenance mode by
depressing [MODE] key.
MAINTENANCE MODE
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
2. Enter Maintenance mode by depressing
[ENTER] key.
MEN: METHOD PROGRAM
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
3. Select each file in Maintenance Mode by
depressing [TARE] or [UNIT WEIGHT] key.
MEN: MEMORY DELETE
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
4. Enter the displayed mode by depressing
[ENTER] key
DEL = ALL MEMORY
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
Note) Each file is changed in loop routine with [TARE] or [UNIT WEIGHT] key.