94
3.4 Print Adjustment
These options in this mode may control print performance. In most cases, these values
will not be needed to be changed at customer side.
Print performance can be controlled by setting Feed Value, Level of Detection, and Print
Contrast.
3.4a Feed Value Program
This measurement is factory set to 0, if the correct label size are set at PRINT SPEC.
However, if the print position is not proper, use this option to adjust the label present to
the proper value for printing.
F E E D V A L U E =
0
♦ ♦ ♦ ♦
• • • • • • • • • • • • • • • • • • • •
Z S T K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
Key Functions : [ + ] key is used for the increment of the feed value. (Max = +127)
[ - ] key is used for the decrement of the feed value. (Max = -127)
[→ (feed )] key is used for feeding label to check the proper feed value.
Programming Feed Value
1. Select Print Adjustment Mode in
Maintenance Mode by depressing [TARE←]
MEN: PRINT ADJUSTMENT
or [U.W→] keys.
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
2. Depress [ENTER] key.
ADJ = FEED VALUE
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
3. Enter FEED VALUE setting Mode by